The specific limitations will depend on the printer used. These are our generic guidelines for our parts-printing service, which are common for COR printed on typical 385nm DLP systems.
Feature Type | Size |
---|---|
Unsupported Wall Thickness | 2.5 mm |
Supported Wall Thickness | 1.25 mm |
Maximum Horizontal Bridge | 3 mm |
Unsupported Angle From Horizontal | 30 ° |
XY Hole Size | 1 mm |
Z Hole Size | 1 mm |
The polySpectra team can help with application-specific design requirements, including microfluidic channels, thin-walled dental and medical devices, and electronics connectors. Please contact [email protected] if you have special design restrictions.